SQA Review Record: SSD-001

Metadata

Key Value
ID RC-003
CrossReference SSD-001, QC-SSD-001

Version History

Date Status Author Reviewer Change Commit
2026-10-05 Proposed Jens Tirsvad Nielsen S02 Initial version 02875ae

Artifact Under Review

Checklist Results

# Criterion Status Evidence/Notes
1 Input/output messages match the corresponding Use Case's main success scenario step-for-step Pass Two operations cover the actor-system exchange of steps 1 to 3; steps 4 to 10 are internal to the system and the SSD says so.
2 Actor and System are treated strictly as black boxes (system shown as :System) Pass Only the Maintainer and :System appear.
3 Object creation/destruction of the System instance handled explicitly where relevant Pass Lifecycle Notes describe one run of the system.
4 Return values are shown for operations that produce one, using dashed return arrows Pass Dashed returns for the prompt set, the checks and the summary.
5 Alternate/exceptional flows are represented separately (or explicitly out of scope noted) Pass Failure flows are stated as out of scope.
6 Message names are verb phrases consistent with the use case's system responsibilities Pass startProjectCreation and provideProjectDetails.
7 Diagram references the specific Use Case (name and ID) it depicts Pass Names UC-001 and the main success scenario.

Overall Verdict

Go — All mandatory criteria pass. Author and reviewer are the same person for now (S01 and S02 are both held by the Maintainer), so the framework's independence rule is not met; re-review when a second person takes S02.